Our team replaced the client’s existing tank water heater with a Navien 240A2 tankless water heater, featuring a built-in recirculation pump and check valve for enhanced efficiency. The installation included running drains into the washer on the other side of the wall for proper drainage.

We added an expansion tank, installed new PVC venting, and adjusted the water and gas lines to ensure secure and accurate connections. Hot and cold isolation valves, a recirculation shut-off valve, and a condensate drain line were also installed.